1. مواصفة |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.Switch over between two power suppliers
2.Automatic Selection of batter supply
3.Switch over time less than 4s
4.Any two AC power supplies with sinusoidal output, high adaptability
5.Provide RS485 communication and Dry contact, support SNMP remote |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
نموذج |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Single cut type |
UP-STS16S |
UP-STS25S |
UP-STS32S |
UP-STS40S |
UP-STS45S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Double cut type |
UP-STS16D |
UP-STS25D |
UP-STS32D |
UP-STS40D |
UP-STS45D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase |
Single Phase |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
التيار الخارج |
16أ |
25أ |
32أ |
40أ |
45أ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max allow current |
18أ |
28أ |
35أ |
45أ |
50أ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
مدخلات التيار المتردد |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC Input voltage |
110فراغ/220 فولت |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input voltage range |
90~130Vac@110Vac; 190~260Vac@220Vac |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
جهد العمل صالح |
±12%, رد فعل عنيف ± 5 فولت |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
تكرر |
50هرتز / 60 هرتز(set in factory) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power off voltage |
110الخامس: ≤55Vac Or ≥135Vac,backlash±5V≤55Vac Or ≥135Vac,backlash±5V 220V: ≤190Vac Or ≥260Vac,backlash±5V≤190Vac Or ≥260Vac,رد فعل عنيف ± 5 فولت |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
تردد انقطاع التيار الكهربائي |
≤45Hz or ≥65Hz,التيار الكهربائي الجهد = ± 0.2 هرتز |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
تبديل الوقت |
<4آنسة |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
× 88 × 385 |
Load current is 110%, operating continuously
Load current> 110%, immediately shut-off; |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Working Environment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
قوة عازلة |
2000Vac/10mA/60s |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Humiditty |
0%~ 90٪, لا تكثيف الرطوبة |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Work temperature |
-25℃~50℃ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
درجة حرارة التخزين |
-40℃ ~ 70 ℃ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
العمل المستمر بعد 1 دقيقة الاغلاق
تيار الحمل > 150٪(1العمل المستمر بعد 1 دقيقة الاغلاق
تيار الحمل > 150٪) |
<55dB |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
مقاس(◆ تعتمد وحدة العاكس تقنية SPWM المتقدمة عالية التردد ومضاعفة التردد أحادي القطب) |
482*44.5*343(1◆ تعتمد وحدة العاكس تقنية SPWM المتقدمة عالية التردد ومضاعفة التردد أحادي القطب) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Communitcation |
RS485/SNMP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|